| Model |
Type |
Freq. Range |
Typical Size (m) |
Application |
Descriptions |
| QTK-CDC-S |
Semi |
30MHz to
1GHz |
1.7x3x3(h)
2.7x4x3(h)
3.8x4x3(h)
4.8x4x4(h)
5.Other |
CISPR/EN 550xx FCC/VCCI…
(pre-compliance) |
- With reflection ground plane.
- Correction test with standard test site is needed.
- Limited NSA measurement is possible.
- Only ferrite tile fully lining in side the walls
and Ceiling.
- For any standard requires a RE measurement Cover
30-1000MHz.
|
| QTK-CDC-F |
Fully |
30MHz to
18GHz or
above |
1.7x3x3(h)
2.7x4x3(h)
3.8x4x3(h)
4.8x4x4(h)
5.Other |
CISPR/EN 550xx
FCC/VCCI…
(Pre-compliance) |
- Without reflection ground plane.
- Correction test with standard test site is needed
for RE.
- Limited free space NSA measurement is possible.
- Field uniformity zone (1.5x1.5m).
- Ferrite tile fully and hybrid absorber fully / partial
lining in side the chamber.
- For any standard requires a RE measurement cover
30-1000MHz and above.
|
IEC 61000-4-3
ETSI 300 xxx
(Fully compliance) |
| QTK-CDC-MS |
Modified
Semi |
30MHz to
18GHz or
above |
1.7x3x3(h)
2.7x4x3(h)
3.8x4x3(h)
4.8x4x4(h)
5.Other |
CISPR/EN 550xx
FCC/VCCI…
(Pre-compliance) |
- With reflection ground plane.
- Correction test with standard test site is needed
for RE.
- Limited free space NSA measurement is possible.
- Field uniformity zone (1.5x1.5m).
- Ferrite tile fully and hybrid absorber fully / partial
lining in side the walls and ceiling and partial on
floor.
- For any standard requires a RE measurement cover
30-1000MHz and above.
|
IEC 61000-4-3
ETSI 300 xxx
(Fully complinace) |
| QTK-STD-3M |
Semi |
Up to 1GHz
(Or 18GHz) |
9x6x6(h) or
more |
CISPR/EN 550xx
FCC/VCCI…
(Fully-compliae) |
- With reflection ground plane.
- NSA guaranteed +/- 3.5dB or lower.(30-1000MHz)
- Ferrite tile fully and hybrid absorber partial lining
side the walls and ceiling.
|
CISPR/EN 550xx
FCC/VCCI…
(Above 1GHz) |
- By adding absorbing material on the floor.
- VSWR according to latest std. is guaranteed. (above
1GHz)
- Field uniformity zone (1.5x1.5m).
|
| QTK-STD-10M |
Semi |
Up to 1GHz
(Or 18GHz) |
22x13x9(h) or
more |
IEC 61000-4-3
CISPR/EN 550xx
FCC/VCCI…
(Fully-compliance) |
- With reflection ground plane.
- NSA guaranteed +/- 3.5dB or lower.(30-1000MHz)
- Ferrite tile fully and hybrid absorber partial lining
side the walls and ceiling.
- Two antenna system is possible.
|
CISPR/EN 550xx
FCC/VCCI…..
(Above 1GHz) |
- By adding absorbing material on the floor.
- VSWR according to latest std. is guaranteed.
(above 1GHz)
- Field uniformity zone (1.5x1.5m).
|
| QTK-STD-F |
Fully |
30MHz to
18GHz or
more |
12x7x7(h)
10x5x5(h)
11x6x6(h) |
IEC 61000-4-3
IEC 61000-4-3
ETSI 300 xxx
(fully complinace) |
- Without reflection ground plane.
- Correction test with standard test site is needed
for RE/EMI.
- Free space NSA +/-4.0dB
- Field uniformity zone (1.5x1.5m).
- VSWR according to latest std. is guaranteed. (above
1GHz)
- Ferrite tile and hybrid absorber fully lining in
side the chamber.
- For any standard requires a RE measurement Cover
30-1000MHz and above in free quasi free space environment.
|
| QTK-ANT |
Fully |
400MHz to
18GHz
|
5x5x5
4x4x4
2x2x2 |
Antenna
parameter
measurement
in 3D |
- Without reflection ground plane.
- Ripple measurement better than -30dB Reflectivity.
- For Arch (gantry arm) measurement system.
- A supplier of chamber for Satimo system.
|
| QTK-SR |
X |
10kHz to
40GHz |
Kinds
(Shielding box) |
For a measurement
needs to isolate
the EM environment |
- Pan type modular system
- Customized size available
- Meets EN 50147-1 requirement or better.
|
All shielding enclosure meets the specifications measured
according to EN 50147-1, IEEE 299 (MIL STD 285)
NSA Reference Standard: ANSI C63.4 / EN 50147-2 / CISPR 16-1-4
Free Space NSA reference standard : prEN 50147-3 / CISPR 16-1-4